Impact, TX, USA
28 days ago
Onsite Mechanical Engineer - Liquid Cooling SME - Critical Facilities

Onsite Mechanical Engineer - Liquid Cooling SME - Critical Facilities - Impact, TX
This opportunity is working onsite at a HPC / Hyperscale Data Center Facility. This firm provides data center solutions custom-fit to the requirements of their client's mission-critical operational facilities. They provide reliability of mission-critical facilities for many of the world's largest organizations (Enterprise and Hyperscale Customers).  This role offers exciting projects that incorporate cutting-edge liquid cooling, HVAC, and mechanical infrastructure technologies.

Our client is seeking an Onsite Mechanical Engineer to act as a Subject Matter Expert  / SME in liquid cooling at the rack level for Hyperscale client onsite at a the Customer's Data Center. They will provide onsite design, commissioning consulting and management expertise in Data Center / Mission Critical Facilities Space with the mindset to provide reliability, energy efficiency, and sustainable design when providing these consulting services. This career-growth minded opportunity offers leading-edge technology and innovation as well as competitive salaries and benefits.

The ideal candidate will have past experience with Mechanical , HVAC and Controls Systems specifically for large data centers / Hyperscale. They will have experience and in-depth knowledge of HVAC / Mechanical / Controls System design, installation, commissioning and operations. This role will support ongoing facility operations, upgrades, and infrastructure deployments with a strong focus on HVAC, liquid cooling at Rack and Server, piping and other mechanical systems used in hyperscale / HPC data center environments.

Responsibilities:

Oversee projects, assist with design- plans, provide and gather specifications, and execute assignments in a multidisciplinary mechanical engineering design role for large sized data center facility design projectsServe as the mechanical subject matter expert onsite in meetings and throughout engineering, commissioning, and go liveAssist with Conceptual Designs gathered from meetings with the client and translate to field-level executionSupport data center operations with design upgrades, retrofits, and equipment assessments for mechanical and cooling systemsReview mechanical design criteria, specifications, drawings, equipment submittals, and other documentation pertinent to engineering design and commissioningWork with Management to create / respond to RFPsRepresent the company in: commissioning, design, construction and coordination meetingsParticipate in onsite commissioning efforts including HVAC systems, chilled water systems, CRAHs, cooling towers, and liquid cooling infrastructureUnderstand functional tests for various systems, such as: HVAC / Mechanical Systems, Controls, etc.Interface with clients, contractors, equipment vendors and owners agents and internal stakeholders as needed;Execute project assignments; Interface with project contractors, vendors, and testing technicians; Interact with all facets of the company: engineering, design, when requestedWrite comprehensive technical reports when needed which including system analysis, deficiency lists, and O&M documentation in addition to: recommendations for optimizing building operations, functional checklists, list of deficiencies, equipment operation and maintenance manualsTroubleshoot HVAC and cooling systems in the field; identify and resolve equipment performance issuesAssist with quality control processes and mechanical system validation procedures

Qualifications:

5–10 years of experience in Mechanical systems, HVAC, or liquid cooling infrastructure for critical facilities or data centersBachelor's Degree in Mechanical Engineering or similar engineering degree a plusLicensed PE / EIT a PlusExperience with AutoCAD for minor tweaks for any design plans a plusPrevious experience using: Revit MEP projects, BIM a plusExperience with Mechanical Systems ( HVAC , Liquid Cooling, Manifolds, Cooling Towers, CFD ( Fluid Dynamics), Boilers , Chillers , Pumps , CRAC / CRAH Units , Air Handling Units , etc. )Familiarity with mechanical equipment testing, balancing, equipment sizing, calculations, and commissioning in high-uptime data center facilitiesPrevious Data Center / Mission Critical experience a mustAbility to successfully work independentlyExcellent communication skills, both written and verbal (this role requires heavy amount of writing, documentation, and client interaction)Self Starter, self motivated, and should prioritize wellPrevious experience in the Military / Military Veterans a huge plus! Experience with Electrical / Mechanical: Navy nukes - EMN, ETN, MMNs, Seabees, Army - Power Generation, Air Force – Power Production, Generator Techs, Maritime, Coast Guard, Army National Guard, etc.

Submittal Instructions:
Please apply directly by clicking the link below, alternatively you can forward your resume directly to: 9cjpge9ca6yymknjn6orczw3yw@crelate.net

After applying, if you have further questions, you may call 973-895-5200 and ask for Iggy. You can also submit via our career portal and take a look at other Critical Facility openings we are working on at, https://www.pkaza.com/jobs/

If this job is not for you, feel free to forward this along. WE PAY FOR REFERRALS!!

Company offers competitive salaries and benefits package including medical insurance, a 401(k) plan
EOE/AA Employer M/F/D/V
Pkaza LLC is a third-party employment firm. All fees assessed by Pkaza LLC will be paid by our employer that we represent and not by the candidate

Por favor confirme su dirección de correo electrónico: Send Email